Workplace performance of a loose-fitting powered air purifying respirator during nanoparticle synthesis
Nanoparticle (particles with diameter ≤100 nm) exposure is recognized as a potentially harmful size fraction for pulmonary particle exposure. During nanoparticle synthesis, the number concentrations in the process room may exceed 10 × 106 cm−3. During such conditions, it is essential that the occupants in the room wear highly reliable high-performance respirators to prevent inhalation exposure. Here we have studied the in-use program protection factor (PPF) of loose-fitting powered air purifying respirators, while workers were coating components with TiO2 or Cu x O y nanoparticles...
Mesure des facteurs de protection des appareils de protection respiratoire vis-à-vis des nanoparticules
L’utilisation des nanoparticules dans l’industrie a augmenté de manière spectaculaire ces dernières années. Les particules de taille nanométrique pourraient donc être à l’origine de nouvelles situations d’exposition professionnelle. Du fait de leur taille, celles-ci peuvent se déposer dans les voies respiratoires et pourraient même atteindre le système nerveux via les voies nasales de sorte que le port d’Appareils de Protection Respiratoire est généralement préconisé dans...